Dark Light
,

MIC-5001 Insulation Resistance Meters

Availability:

5 in stock


 

  • Continuous reading of measured insulation resistance or leakage current
  • Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
  • Sound signalling of fi ve-second time intervals, facilitating capture of time characteristics
  • Timing of measurement time T1, T2 and T3 for measurement of dielectric absorption ratio (DAR) and polarization index (PI)
  • Reading of actual measurement voltage during measurement
  • Protection against measurement of live objects
  • Two- or three-lead method of insulation resistance measurement
  • Power supplied by accumulator
  • Instruments meet the requirements laid down by standard EN 61557
  • The meter can be powered and charged from an external power adapter or from a car lighter socke

69,000.00 

5 in stock

*
Compare

Specification

MIC-5001 Insulation Resistance Meters

  • Continuous reading of measured insulation resistance or leakage current
  • Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
  • Sound signalling of fi ve-second time intervals, facilitating capture of time characteristics
  • Timing of measurement time T1, T2 and T3 for measurement of dielectric absorption ratio (DAR) and polarization index (PI)
  • Reading of actual measurement voltage during measurement
  • Protection against measurement of live objects
  • Two- or three-lead method of insulation resistance measurement
  • Power supplied by accumulator
  • Instruments meet the requirements laid down by standard EN 61557
  • The meter can be powered and charged from an external power adapter or from a car lighter socket

Technical Data

Insulation resistance measurement

Measurement range acc. to IEC 61557-2 for \(R_{ISOmin}=\frac{U_{ISOnom}}{I_{ISOnom}}\)…5 TΩ

Range

Resolution

Accuracy

0.0…999.9 kΩ

0.1 kΩ

± (3% m.v. + 20 digits)

1.000…9.999 MΩ

0.001 MΩ

± (3% m.v. + 20 digits)

1.00…99.99 MΩ

0.01 MΩ

± (3% m.v. + 20 digits)

100.0…999.9 MΩ

0.1 MΩ

± (3% m.v. + 20 digits)

1.000…9.999 GΩ

0.001 GΩ

± (3% m.v. + 20 digits)

10.00…99.99 GΩ

0.01 GΩ

± (3% m.v. + 20 digits)

100.0…999.9 GΩ

0.1 GΩ

± (3% m.v. + 20 digits)

1.000…5.000 TΩ

0.001 TΩ

± (4% m.v. + 50 digits)

Values of measured resistance depending on measuring voltage

Voltage UISO

Measurement range

up to 100 V

50 GΩ

200 V…400 V

100 GΩ

500 V…900 V

250 GΩ

1000 V…2400 V

500 GΩ

2500 V

2500 GΩ

5000 V

5000 GΩ

RampTest insulation resistance measurement

Range

Resolution

Accuracy

0.0…999.9 kΩ

0.1 kΩ

±(5% m.v. + 40 digits)

1.000…9.999 MΩ

0.001 MΩ

±(5% m.v. + 40 digits)

10.00…99.99 MΩ

0.01 MΩ

±(5% m.v. + 40 digits)

100.0…999.9 MΩ

0.1 MΩ

±(5% m.v. + 40 digits)

1.000…9.999 GΩ

0.001 GΩ

±(5% m.v. + 40 digits)

10.00…99.99 GΩ

0.01 GΩ

±(5% m.v. + 40 digits)

100.0…999.9 GΩ

0.1 GΩ

±(5% m.v. + 40 digits)

1.000…4.999 TΩ

0.001 TΩ

±(5% m.v. + 40 digits)

The measurement of breakdown voltage in RampTest mode

Range

Resolution

Chosen UISO

Accuracy

25.0 V…99.0 V

0.1 V

≤600 V

± (5% m.v. + 10 digits)

100 V…600 V

1 V

≤600 V

± (5% m.v. + 4 digits)

25 V…999 V

1 V

>600 V

± (5% m.v. + 5 digits)

1.00 kV…5.00 kV

10 V

>600 V

± (5% m.v. + 4 digits)

DC and AC voltage measurement

Range

Resolution

Accuracy

0…299.9 V

0.1 V

±(3% m.v. + 2 digits)

300…750 V

1 V

±(3% m.v. + 2 digits)

Downloads

Technical Datasheets – MIC-5001 Insulation Resistance Meters

Technical Manual – MIC-5001 Insulation Resistance Meters

Select at least 2 products