Dark Light
-10%
,

Fluke 317/319 Clamp Meters

Availability:

33 in stock


  • Unique 40A high-precision low current measurement–0.01A high-resolution, 1.6% high-precision measurement
  • The clamps are slim, lightweight, and portable, making them ideal for use in small, confined spaces
  • The large backlight display facilitates readings in dark environments
  • Current frequency measurement
  • Precision down to 0.01A and 0.1V
  • 1000A/600A AC/DC current measurement (319/317)
  • 600V AC/DC voltage measurement
  • 4000Ω resistance measurement
  • Continuity beeper
  • One year warranty

20,610.00  22,900.00 

33 in stock

*

Product Description

The Fluke 317 and 319 are designed with ergonomic concepts, shaped to fit your hand and to access tight spots easily. These small and rugged clamp meters are ideally suited for current measurements up to 1000 A (319) in tight cable compartments. The Fluke 317and 319 also offer AC/DC current measurements and has a higher resolution for loads below 40 A. In addition to a compact package with a strong feature set, the Fluke 319 also equip with In-rush current and Frequency functions for testing motors, lighting, etc.

Technical data

General Specifications

General Specifications

General specifications

Digital display

6000 count resolution

Low battery Indication

Displays a signal when the batteries are below their required voltage

Power source

Three AAA IEC LR03 batteries

Clamp opening size

1.45 in (37 mm)

Jaw diameter

1.45 in (37 mm)

Dimensions (L x W x H)

9.21 in x 2.95 in x 1.37 in
(234.0 mm x 75.0 mm x 34.8 mm)

Weight

Approximately 13.5 oz (384 g) (batteries included)

Auto range

Available in Ohms

Safety

CE
EN/IEC 61010-1 and IEC 61010-2-032
Measurement Category: 600V CAT III

Size

207 x 75 x 34

Environmental specifications

Operating temperature

14°F to 122°F (-10 °C to 50 °C)

Storage temperature

-40 °F to 140 °F (-40 °C to 60 °C)

Operating altitude

1 mile (2000 meters) above mean sea level

Storage altitude

7 miles (12,000 meters) above mean sea level

IP Rating

IP40

Vibration requirements

Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis

Drop test requirements

3 ft (1 m) drop test, six sides, oak floor

EMI, RFI, EMC

Instrument unspecified for use in EMC field ≥ 0.1 V/m

Temperature coefficients

0.1x (specified accuracy)/ °C
(<64 °F or > 82° F)
(<18 °C or > 28 °C)

Operating humidity

Non-condensing (< 50 °F) (< 10 °C)
90% RH (50 °F to 86 °F) (10 °C to 30 °C)
75% RH (86 °F to 104 °F) (30 °C to 40 °C)
45% RH (104 °F to 122 °F) (40 °C to 50 °C)
(Without condensation)

Downloads

Datasheet : Fluke 317/319 Clamp Meters

Instruction Manual : Fluke 317/319 Clamp Meters