HANDHELD DEVICES, MULTIMETERS, Sonel
CMM-40 Multimeters
Availability:
10 in stock
- MAX and MIN function for saving extreme values
- AC+DC function for reading the sum of an alternating and direct component
- REL mode for relative measurement to a stored reference value
- PEAK Hold for displaying the peak value of the measured parameter.
15,220.00 ₹ 21,512.00 ₹
10 in stock
CompareRelated products
-
ELECTRICAL SAFETY MEASUREMENTS, SHORT CIRCUIT LOOP MEASUREMENTS, Sonel
MZC-304F
0 out of 5(0)- Fault loop impedance measurement with 0.01 Ω resolution.
- Low-current impedance measurement in circuits protected by RCD ≥ 30mA with 0.01 Ω resolution (range of 180…270 V)
- Operates in networks with voltages 220/380 V, 230 V/400 V, 240/415 V (operating range 180…460 V)
- Operating voltage range: 180…270 V (for ZL-PE and ZL-N) and 180…460 V (for ZL-L).
- Maximum measuring current: 7.6 A for 230 V (3×10 ms), 13.3 A for 400 V (3×10 ms).
- Operating frequency 45…65 Hz
- Calculation of Ik fault current.
- Measurement with swapped L and N conductors.
- Measurement of resistance (RS) and reactance (XS) components.
- Low-voltage measurement of continuity of circuit and resistance.
SKU: n/a -
Short Circuit Loop Measurements, Sonel
MZC-330S
0 out of 5(0)- Measurement of very low short circuit loop impedances (with resolution 0,1 mΩ) with a current of 130 A at 230 V; maximum 300 A at 690 V.
- Measurement with a current of 24 A at 230 V, maximum 37 A at 690 V with resolution 0,01 Ω.
- Measurements in installations with rated voltages: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V and frequencies 45…65 Hz.
- Ability to perform measurements in short circuit system: phase-phase, phase-PE, phase-N.
- Differentiation between the phase voltage and the inter-phase voltage while calculating the short circuit current.
- Ability to change the length of test lead (measurement with 2p method).
- 4p (four-pole) method, test leads do not require calibration (measurement with current up to 300 A).
- Measurement of resistance (RS) and reactance (XS) components.
SKU: n/a -
Multifunction electrical installations meters, Sonel
MPI-530 Multifunction Electrical Installations Meter
Multifunction electrical installations meters, SonelMPI-530 Multifunction Electrical Installations Meter
0 out of 5(0)- Short circuit loop impedance (also in circuits secured with RCDs)
- RCD parameters
- Insulation resistance
- Earth resistance (4 measurement methods + soil resistivity measurement)
- Continuity of protective and equipotential bondings
- Light intensity measurement
- Phase sequence test
- Motor rotation direction test.
SKU: n/a -
Insulation resistance meters, Sonel
MIC-2501 Insulation Resistance Meters
0 out of 5(0)- Measurement voltage within the range of 100…2500 V, selected in steps of 100 V
- Continuous reading of measured insulation resistance or leakage current
- Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement,
- Sound signalling of five-second time intervals, facilitating capture of time characteristics
- Timed measurement times T1 , T2 and T3 for measurement of absorption coefficients (Ab/PI/DAR) at 15, 60 and 600 s and polarization index
- Reading of actual measurement voltage during measurement
- Protection against measurement of live objects
SKU: n/a