Dark Light
-28%
,

Universal Calibrator uCAL UC12

Availability:

15 in stock


  • Compact, handheld, User friendly menu
  • Available with EMI/EMC compliance
  • Easy to read Color Graphical TFT LCD display
  • Rechargeable lithium Ion battery with enhanced power control for prolonged battery life
  • Measure: mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse
  • Source: mA/ V/ mV/ mA(2W)/ Resistance/ RTD/ TC/ Frequency/ Pulse
  • 24 VDC Loop power Supply to power transmitters and loops
  • Step/Ramp functions with Auto/Man selection

84,999.00  118,500.00 

15 in stock

*

Product Description

Masibus uCAL model UC12 Universal Calibrator is the compact, rugged and easy to use hand held device with graphical user interface for precise measuring and sourcing of electrical and physical parameters. Masibus UC12 Universal Calibrator is designed to provide the best accuracy in all modes of operation.

UC12 has Source and Measurement capability with independent parameter and range selection for Source and Measure. UC12 has mA/ V/ mV/ mA (24V)/ Switch-test / RTD/ TC/ Frequency/ Pulse measurement capability and also has mA/ V/ mV/ mA (2W)/Resistance/ RTD/ TC/ Frequency/ Pulse source capability.

There is an isolation between measure and source/ measure sections. UC12 Universal Calibrator has easy to operate short cut keys SCR1 and SCR2 for input selection for measure and source/ measure respectively. Automatic step/ ramp output with Auto/ Man selection, data logging, Max/ Min/ Average values, scaling to Engineering units and filter settings enhances the use of Universal Calibrator.

It has been designed to give maximum Battery life on full charge, the backlight is adjustable for power saving and the display can be programmed to automatically enable the glance screen when not in use.

UC12 comes with a Mini USB connector for charging, logged data retrieval and firmware upgrade. Standard accessories provided are patch cables, charger, USB cable, instruction manual, logged data retrieval software CD and calibration certificate, all in an attractive carrying case.

Technical data

Electrical Measurement Parameters and Accuracy

Parameter

Range

Resolution

Accuracy

V

0 to 30.00 VDC

0.001 V

±0.02% of reading ± 2 count

mA

0 to 24.000 mA

0.001 mA

±0.02% of reading ± 2 count

Electrical Simulation Parameters and Accuracy

Parameter

Range

Resolution

Accuracy

V

0 to 12.000 VDC

0.001 V

±0.02% of reading ± 2 count

mA

0 to 24.000 mA

0.001 mA

±0.02% of reading ± 2 count

Thermocouple/mV Measurement /Simulation Resolution and Accuracy

TC Type

Range

Resolution

Accuracy

E
J
K
T
B
R
S
N

mV

-200.0 to 1000.0 °C
-200.0 to 1200.0 °C
-200.0 to 1372.0 °C
-200.0 to 400.0 °C
450.0 to 1800.0 °C
0.0 to 1750.0 °C
0 to 1750.0 °C
-200.0 to 1300.0°C

-10.000 to 80.000 mV
-10.00 to 250.00 mV

0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C
0.1 °C

0.001 mV
0.01mV

0.3 °C
0.3 °C
0.5 °C
0.3 °C
0.3 °C
0.3 °C
0.5 °C
0.5 °C

±0.02% of reading ± 4uV ±0.02% of reading ± 0.02mV

Frequency Measurement

Range

Resolution

0.0143 to 9.9999
10 to 99.999Hz
100 to 999.99Hz
1000 to 9999.9 Hz
10000 to 50000 Hz

0.0001 Hz
0.001 Hz
0.01 Hz
0.1 Hz
1 Hz

Feature

Specification

Trigger Level

0 to 12V in 1 V Steps

Accuracy

±0.01% of Reading ± 1 count

Supported units

Hz, KHz, cph, cpm, sec, msec, usec

Pulse Counting

Feature

Specification

Range

0 to 999999 pulses

Trigger Level

0 to 12V in 1 V Steps

Frequency Generation

Range

Resolution

0.0005 to 0.5Hz
0.5 to 50 Hz
50 to 500 Hz
500 to 5000 Hz
5000 to 10000 Hz

0.00001 Hz
0.0001 Hz
0.001 Hz
0.01 Hz
0.1 Hz

Feature

Specification

Output Amplitude positive Square wave

0 to 12VPP (±0.5V)

Output Amplitude symmetric Square wave

0 to 6 VPP (±0.5V)

Accuracy

±0.02% of Reading ± 2 count

Duty Cycle

1 to 99% (up to 500Hz

Supported units

Hz, KHz, cph, cpm, sec, msec, usec

Pulse Generation

Feature

Specification

Range Resolution

0 to 999999 pulses

Resolution

1 Pulse

Output Amplitude positive
Square wave

0 to 12VPP (±0.5V)

Output Amplitude symmetric
Square wave

0 to 6 VPP (±0.5V)

Pulse Frequency

0.0005 to 10000Hz

Duty Cycle

1 to 99% (up to 500Hz)

Downloads

Datasheet : Universal Calibrator uCAL UC12

Instruction Manual : Universal Calibrator uCAL UC12

Delivery Scope

  • Calibrating and checking temperature indicator/ controllers, recorders, temperature transmitters, single conditioners, etc.