  • Input Types: Supports Thermocouples (J, K, T, N, R, S, B, E), RTDs (Pt100, Pt1000), NTC thermistors, and voltage inputs (0-50 mV).
  • Output Type: 4-20 mA current loop
  • Output Resolution: 0.25 µA
  • Thermal Drift: < 0.05% per 25 °C (77 °F)
  • Isolation (Input-Output): 1.5 kVrms
  • Electrical Protection: Reverse polarity protection
  • HART® Version: HART V7, compatible with HART V5
  • Configuration Interface: Through TxConfig-HRT adapter or HART® certified handheld devices
  • Configuration Software: TxConfig II
  • Approvals / Regulations: CE, NAMUR NE43, RoHS, REACH, HART®

9,900.00  21,450.00 

33 in stock

*
Compare

Specifications

The resilience of NOVUS devices and the established quality of HART® certification are combined in the temperature transmitter TxIsoRail-HRT. The transmitter supports voltage spikes up to 1.5 kVrms and offers electrical isolation between input and output. It is compatible with devices that have earned the HART® certification. The main difference is that it has two 4-20 mA current loop wires for total configuration, which means more functionality for monitoring and device setting.

NOVUS’s temperature transmitter TxIsoRail-HRT uses a globally recognized protocol with over 40 million field instruments that accept HART® technology. This allows users to have flexibility by using standard HART® configuration and supervision software.

A versatile DIN rail mount temperature transmitter that is essential to many industrial processes is the TxIsoRail-HRT. Its universal input can be set up to read mV signals, thermocouples, and RTDs. It has detachable connectors.
In accordance with the specified range, it transforms the input signal into a linear output of 4–20 mA. TxIsoRail-HRT communicates via the 4–20 mA output current loop using the HART® communication protocol.
Electrical isolation between the input and output improves both system and user safety.

The resilience of NOVUS devices and the established quality of HART® certification are combined in the temperature transmitter TxIsoRail-HRT. The transmitter supports voltage spikes up to 1.5 kVrms and offers electrical isolation between input and output. It is compatible with devices that have earned the HART® certification. The main difference is that it has two 4-20 mA current loop wires for total configuration, which means more functionality for monitoring and device setting.

NOVUS’s temperature transmitter TxIsoRail-HRT uses a globally recognized protocol with over 40 million field instruments that accept HART® technology. This allows users to have flexibility by using standard HART® configuration and supervision software.

A versatile DIN rail mount temperature transmitter that is essential to many industrial processes is the TxIsoRail-HRT. Its universal input can be set up to read mV signals, thermocouples, and RTDs. It has detachable connectors.
In accordance with the specified range, it transforms the input signal into a linear output of 4–20 mA. TxIsoRail-HRT communicates via the 4–20 mA output current loop using the HART® communication protocol.
Electrical isolation between the input and output improves both system and user safety.

Technical Data

Specification

Input Type

J, K, T, N, R, S, B, E, Pt100, Pt1000, NTC and 0-50 mV

Accuracy Typical

Pt1000 / mV: 0.07 % span , Pt100: 0.08 % span , T/C: 0.07 % span ±1 °C (1.8 °F) , NTC: 0.2 °C (0.36 °F)

Maximum

Pt1000 / mV: 0.15 % span , Pt100: 0.15 % span , T/C: 0.15 % span ±1 °C (1.8 °F) , NTC: 0.45 °C (0.81 °F)"

Output Type

4-20 mA

Output Resolution

0.25 µA

Thermal Drift

< 0.05 % / 25 °C (77 °F)

Isolation Input-Output

1.5 kVrms

Electric Protection

Reverse Polarity

HART® Version

HART V7, compatible with HART V5

Configuration Interface

Through TxConfig-HRT adapter or HART® certified HandHeld

Configuration Software

TxConfig II

Approvals / Regulations

CE, NAMUR NE43, RoHS, Reach, HART®

Operating Conditions

-40 to 85 °C (-40 to 185 °F) | 0 to 90% RH

Power Supply

4-20 mA Loop Powered (8.5 - 36 Vdc)

Enclosure

ABS UL94-HB

Format / Mounting

35 mm (TS35) DIN Rail

Downloads

Technical Manual – TxIsoRail-HRT HART® Temperature Transmitter

Select at least 2 products
to compare