Dark Light
-10%
,

Fluke 705 Loop Calibrator

Availability:

33 in stock


  • Powerful loop calibrator that provides a very cost effective, integrated solution for calibration, repair, and maintenance of milliamp loops
  • Provides simultaneous mA and % readout for quick, easy interpretation of readings.
  • Delivers mA accuracy of 0.02%
  • Features push button 25% steps for fast, easy linearity checks

51,869.00  57,633.00 

33 in stock

*

Product Description

Fluke 705 loop calibrator provides a cost-effective, integrated solution for calibrating milliamp loops

The Fluke 705 is a cost-effective, integrated solution for calibration, repair and maintenance of milliamp loops. It features a large display and simple, pushbutton interface for ease of use. Plus, it offers the other capabilities you need most to calibrate mA loops including:

  • mA sourcing, simulation and measurement
  • 0.02% accuracy and 0.001 mA resolution
  • Simultaneous mA and % of span display
  • Selectable step or ramp outputs
  • 24 V Loop supply with mA measure
  • 0-28 VDC measurement to check Loop Voltage
  • Easy battery exchange without opening the case
  • Includes “span check” for fast confirmation of zero and span.
  • Provides selectable slow ramp, fast ramp, and step to provide smooth outputs for valve slewing and loop functional tests.
  • Includes a 24 volt internal loop supply, so you can power and read a transmitter at the same time without a DMM.
  • Runs on a single 9 V battery that is easily changed without breaking the calibration seal
  • Offers 0 – 20 mA or 4 – 20 mA default start up modes
  • Comes with a protective yellow holster with test lead storage and a three year warranty

Technical data

General Specifications

General Specifications

Technical specifications

Current measurement

Range 0 to 24 mA
Resolution 0.001 mA
Accuracy 0.02% Rdg + 2 LSD

Current sourcing

Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.025% Rdg + 2 LSD
Drive capability 1000 Ω @ 24 mA

Current simulation

Range 0 to 20 mA or 4 to 20 mA
Accuracy 0.025% Rdg + 2 LSD
Ext. loop voltage requirement 12-30 V

Voltage measurement

Range 0 to 28 V DC
Resolution 1 mV
Accuracy 0.025% Rdg + 2 LSD

Loop power

While measuring mA, 24 V

Environmental specifications

Operating temperature

-10°C to 55°C

Storage temperature

-40°C to 60°C

Humidity (without condensation)

0 to 90% (0°C to 35°C); 0 to 70% (35°C to 55°C)

Temperature coefficient

-10°C to 18°C, 28°C to 55°C, ±.005% of range per°C

Safety specifications

Safety

CSA C22.2 No. 1010.1:1992

EMC

EN50082-1:1992 and EN55022:1994 Class B

Maximum voltage

30 V

Mechanical and General Specifications

Size

152 x 70 x 41 mm

Weight

340 g

Batteries

One 9 V battery

Warranty

Three years

Shock and vibration

per MIL-T-28800 for a Class 2 Instrument

Display current and % of span

Yes

Auto step, auto ramp

Yes

Span check

Yes

Downloads

Datasheet : Fluke 705 Loop Calibrator

Manual : Fluke 705 Loop Calibrator