Shop
Showing 181–192 of 268 results
-
ELECTRICAL SAFETY MEASUREMENTS, SHORT CIRCUIT LOOP MEASUREMENTS, Sonel
MZC-304F
- Fault loop impedance measurement with 0.01 Ω resolution.
- Low-current impedance measurement in circuits protected by RCD ≥ 30mA with 0.01 Ω resolution (range of 180…270 V)
- Operates in networks with voltages 220/380 V, 230 V/400 V, 240/415 V (operating range 180…460 V)
- Operating voltage range: 180…270 V (for ZL-PE and ZL-N) and 180…460 V (for ZL-L).
- Maximum measuring current: 7.6 A for 230 V (3×10 ms), 13.3 A for 400 V (3×10 ms).
- Operating frequency 45…65 Hz
- Calculation of Ik fault current.
- Measurement with swapped L and N conductors.
- Measurement of resistance (RS) and reactance (XS) components.
- Low-voltage measurement of continuity of circuit and resistance.
SKU: n/a -
Short Circuit Loop Measurements, Sonel
MZC-306
- Fault loop impedance measurement with 0.01Ω resolution
- Low-current impedance measurement in circuits protected by RCD ≥ 30mA with 0.01 Ω resolution (100…440 V)
- Operates in networks with voltages 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V (operating range 100…750 V)
- Operating frequency 45…65 Hz
- Calculation of fault current
- Automatic differentiation between phase and phase-to-phase voltage
- Possibility of applying 1.2, 5, 10, 20 m test leads or an adapter terminated by a power network plug
- Measurement with swapped L and N conductors
- Measurement of resistance (RS) and reactance (XS) components
SKU: n/a -
Short Circuit Loop Measurements, Sonel
MZC-330S
- Measurement of very low short circuit loop impedances (with resolution 0,1 mΩ) with a current of 130 A at 230 V; maximum 300 A at 690 V.
- Measurement with a current of 24 A at 230 V, maximum 37 A at 690 V with resolution 0,01 Ω.
- Measurements in installations with rated voltages: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V and frequencies 45…65 Hz.
- Ability to perform measurements in short circuit system: phase-phase, phase-PE, phase-N.
- Differentiation between the phase voltage and the inter-phase voltage while calculating the short circuit current.
- Ability to change the length of test lead (measurement with 2p method).
- 4p (four-pole) method, test leads do not require calibration (measurement with current up to 300 A).
- Measurement of resistance (RS) and reactance (XS) components.
SKU: n/a -
Metravi, OSCILLOSCOPE, ANALOGUE OSCILLOSCOPE
OS-5010A Analogue Oscilloscope
- Single Channel Single Trace Oscilloscope
- Bandwidth: 10MHz
- Confirms to EN61010-1 (1993) and EN-IEC61326-1(1997)
- Wide measurement
- High sensitivity and trigger lock
- Sweep switch adopts digital code switch and accuracy
- Proper to use in colleges and for engineers and technicians
- Deflection factor is 5mV~5V/div in 1-2-5 Sequence in 10 steps
- Accuracy: ±5%
- Maximum Input Voltage: 400Vpk
- Sweep deflection factor is 0.1us/div-0.1s/div
SKU: n/a -
Metravi, POWER GUARD / ENERGY METER
PG-01 Power Guard and Energy Meter
- Multifunction Power Meter
- Works on 6A / 230V AC
- Displays Voltage, Current, Power, Power Factor, Frequency, KWh, CO2, Cost of running the equipment.
- Calculates total time consumed
- Calculates cost of electricity consumed
- Retains the readings while load shedding
- Voltage: 100V AC ~ 260V AC
- Current: upto 6A
- Power: 0.5 – 1380W
SKU: n/a -
-
DIFFERENTIAL PRESSURE MANOMETER, Metravi
PM-01 Differential Pressure Manometer
- Differential Pressure Manometer
- Backlit LCD Dual Display
- Low Battery Indication
- Under Range and Over Range Indication
- Fast Response Time
- Battery Operated
- Measuring Range: 0 – 5 PSI
- It measures in various units like inH2O, PSI, bar, mbar, kPa, inHg, mmHg, OZin2, ftH2O, cmH2O, kgcm2.
- With RS-232 PC Interface Facility
- High Accuracy of 0.3%
SKU: n/a -
CALIBRATOR, PROCESS METER, Metravi
PM-29 Process Meter
- Digital Process Calibrator cum Multimeter
- Display: Backlit LCD, 4 digit display for measurement, 5 digit display for output
- Confirms to IEC61010-1 (CATIV 600V, CATIII 1000V, Pollution Level II
- Overload Protection
- Surge Protection
- Developed, designed and produced according to ISO 9001
SKU: n/a -
Power Quality Analysis, Sonel
PQM-700 Power Quality Analysis
- 4 current inputs, physical measurement of current in the neutral conductor.
- Registration of up to 1100 parameters, including average, maximum, minimum and instantaneous values.
- Built-in heater, stable operation at low temperatures down to -20ºC.
- Internal rechargeable battery, autonomy of the meter (min. 6 hours).
- IP65 ingress protection, possibility of work in rain, snow and high humidity
SKU: n/a -
Power Quality Analysis, Sonel
PQM-707 Power Quality Analysis
- 7” touchscreen – ergonomic and intuitive graphical user interface.
- Over 10 years of recording.
- CAT IV 600 V measurement category – high safety.
- All parameters according to class S – high accuracy of measurements.
- Li-Ion rechargeable battery – higher mobility.
- Powering from measured network – reliability of measurements.
- Removable memory card – recording data with no restrictions.
- Quick setup and reporting – ease of use.
- Cooperation with desktop Sonel Analysis software – extended data analysis.
SKU: n/a -
Power Quality Analysis, Sonel
PQM-711 Power Quality Analysis
- Remote control and data transfer through a built-in GSM modem.
- Anti-theft feature – SMS notification in the event of position change (built-in GPS receiver).
- Real-time clock synchronized to GPS protocol.
- Remote control of the analyzer via software: Sonel Analysis (Wi-Fi and GSM for Windows) or Sonel Analysis Mobile (Wi-Fi for Android).
SKU: n/a -
CLAMP METER, DIGITAL TRMS AC/DC CLAMP METER, DIGITAL AC/DC CLAMP METER, Metravi
PRO 419 Digital TRMS AC/DC Clamp Meter
-26%CLAMP METER, DIGITAL TRMS AC/DC CLAMP METER, DIGITAL AC/DC CLAMP METER, MetraviPRO 419 Digital TRMS AC/DC Clamp Meter
- Professional T-RMS AC/DC Clamp Meter
- 4000 Counts, 3-3/4 Digits Backlit LCD Display
- Confirms to CAT-IV 600V, CAT-III 1000V, CE, IEC-61010-1
- 600V AC/DC Protection in all ranges
- 34 mm Clamp Jaw Dia
- Auto Power Off
- Non Contact Voltage Detector
- Flash light in the Jaw to access dark Areas
- Double Injection Housing, providing double insulation
- Data Hold, MAX-MIN Record, Relative Measurement
SKU: n/a