Sonel, THERMAL IMAGERS AND PYROMETERS
KT-128 Thermal Imagers And Pyrometers
Availability:
2 in stock
- Measuring range -20°C…400°C (-20°F… 752°F)
- Quick start
- Fast temperature measurement
- Automatic signalling of exceeded alarm threshold
- Saving IR images to SD card
- Built-in Li-Ion battery with a 5-hour working time
- Interfaces: USB type C, SD slot
- Can be set up on a tripod
72,000.00 ₹ 87,000.00 ₹
2 in stock
CompareRelated products
-
Photovoltaic Measurements, Sonel
IRM-1 MPI
0 out of 5(0)- Measurement of solar radiation and temperature.
- The LoRa interface for communication with a master meter – offers a larger range than the Bluetooth technology!
- Automatic data synchronization with a master meter with reSYNC function.
- Built-in compass and inclination sensor.
- Built-in recorder that can be used to record solar radiation before constructing PV systems, as well as to measure the shading of existing systems.
- Large measurement memory: 999 cache memory cells and 5000 recorder records available (one-time recording) with the option of overwriting them (continuous recording).
SKU: n/a -
ELECTRICAL SAFETY MEASUREMENTS, SHORT CIRCUIT LOOP MEASUREMENTS, Sonel
MZC-304F
0 out of 5(0)- Fault loop impedance measurement with 0.01 Ω resolution.
- Low-current impedance measurement in circuits protected by RCD ≥ 30mA with 0.01 Ω resolution (range of 180…270 V)
- Operates in networks with voltages 220/380 V, 230 V/400 V, 240/415 V (operating range 180…460 V)
- Operating voltage range: 180…270 V (for ZL-PE and ZL-N) and 180…460 V (for ZL-L).
- Maximum measuring current: 7.6 A for 230 V (3×10 ms), 13.3 A for 400 V (3×10 ms).
- Operating frequency 45…65 Hz
- Calculation of Ik fault current.
- Measurement with swapped L and N conductors.
- Measurement of resistance (RS) and reactance (XS) components.
- Low-voltage measurement of continuity of circuit and resistance.
SKU: n/a -
Insulation resistance meters, Sonel
MIC-5001 Insulation Resistance Meters
0 out of 5(0)- Continuous reading of measured insulation resistance or leakage current
- Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
- Sound signalling of fi ve-second time intervals, facilitating capture of time characteristics
- Timing of measurement time T1, T2 and T3 for measurement of dielectric absorption ratio (DAR) and polarization index (PI)
- Reading of actual measurement voltage during measurement
- Protection against measurement of live objects
- Two- or three-lead method of insulation resistance measurement
- Power supplied by accumulator
- Instruments meet the requirements laid down by standard EN 61557
- The meter can be powered and charged from an external power adapter or from a car lighter socke
SKU: n/a -
Insulation resistance meters, Sonel
MIC-2501 Insulation Resistance Meters
0 out of 5(0)- Measurement voltage within the range of 100…2500 V, selected in steps of 100 V
- Continuous reading of measured insulation resistance or leakage current
- Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement,
- Sound signalling of five-second time intervals, facilitating capture of time characteristics
- Timed measurement times T1 , T2 and T3 for measurement of absorption coefficients (Ab/PI/DAR) at 15, 60 and 600 s and polarization index
- Reading of actual measurement voltage during measurement
- Protection against measurement of live objects
SKU: n/a