Dark Light
-10%
,

Fluke 116 Digital HVAC Multimeter

Availability:

33 in stock


  • Digital multimeter designed specifically for HVAC professionals
  • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
  • Provides microamps to test flame sensors
  • Features low input impedance to helps prevent false readings due to ghost voltage
  • Presents a large white LED backlight for working in poorly lit areas

35,398.00  39,332.00 

33 in stock

*

Product Description

The Fluke 116 DMM provides the features you need to quickly troubleshoot HVAC equipment

The Fluke 116 was specifically designed for HVAC professionals. It has everything you need to quickly troubleshoot problems with HVAC equipment and flame sensors, including a built-in thermometer to measure temperatures up to 400°C (752°F) and microamps to test flame sensors. The Fluke 116 also measures resistance, continuity, frequency, and capacitance. And the large white LED backlight makes it easy to see results even in poorly lit areas.

Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

Other useful features:

  • Measures resistance, continuity, frequency, and capacitance
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated

Technical data

General Specifications

General Specifications

Specifications

Maximum Voltage Between any Terminal and Earth Ground

600 V

Safety

IEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V

Fuse for A input

11 A, 1000 V FAST Fuse (Fluke PN 803293)

Bar graph

33 segments, updates 32 per second

Operating temperature

-10℃ to + 50℃

Storage temperature

-40℃ to + 60℃

Battery type

9 volt Alkaline, IEC 6LR61

Battery life

400 hours typical, without backlight

Display

Digital: 6,000 counts, updates 4 per second

Accuracy Specifications

DC millivolts

Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2

DC volts

Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2

Auto volts

Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)

AC millivolts¹ True RMS

Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

AC volts¹ True RMS

Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)

Continuity

Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects
opens or shorts of
500 μs or longer.

Mechanical and General Specifications

Size

167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)

Weight

550 g

Warranty

3 years

Downloads

Datasheet : Fluke 116 Digital HVAC Multimeter