Shop
Showing 169–180 of 268 results
-
Insulation resistance meters, Sonel
MIC-10 Insulation Resistance Meters
- Measurement of insulation resistance up to 100 GΩ thanks to max 1000 V measurement voltage
- Designed for harsh environmental conditions conditions – IP67 ingress protection
- Excellent for repeatable measurements – memory of 12,000 records and UNI-Schuko adapter for sockets
- Allows for testing electrical continuity – RCONT 200 mA function
- Checking start capacitors in motors thanks to capacity measurement function
SKU: n/a -
Insulation resistance meters, Sonel
MIC-10K1 Insulation Resistance Meters
- Continuous indication of measured insulation resistance or leakage current
- Automatic discharge of measured object capacitance-voltage after the end of insulation resistance measurement
- Acoustic signaling of 5-second intervals to facilitate capturing time characteristics
- Adjustable measuring time – up to 99’59’’
- T1, T2, and T3 test times for measuring one or two absorption coefficients from the range of 1…600 s
- Polarization index (PI), absorption coefficients Ab1, Ab2 and dielectric absorption ratio (DAR) measurement
- Indication of actual test voltage during measurement
- 1.2 mA, 3 mA, or 6 mA test current
- Insulation resistance measurement using two- or three-wire method
- Measurements with test leads up to 20 m
- Protection against measuring live objects
SKU: n/a -
Insulation resistance meters, Sonel
MIC-2501 Insulation Resistance Meters
- Measurement voltage within the range of 100…2500 V, selected in steps of 100 V
- Continuous reading of measured insulation resistance or leakage current
- Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement,
- Sound signalling of five-second time intervals, facilitating capture of time characteristics
- Timed measurement times T1 , T2 and T3 for measurement of absorption coefficients (Ab/PI/DAR) at 15, 60 and 600 s and polarization index
- Reading of actual measurement voltage during measurement
- Protection against measurement of live objects
SKU: n/a -
Insulation resistance meters, Sonel
MIC-30 Insulation Resistance Meters
- Measurement of insulation resistance up to 100 GΩ thanks to max 1000 V measurement voltage
- Designed for harsh environmental conditions conditions – IP67 ingress protection
- Excellent for repeatable measurements – memory of 12,000 records and UNI-Schuko adapter for sockets
- Allows for testing electrical continuity – RCONT 200 mA function
- Checking start capacitors in motors thanks to capacity measurement function
SKU: n/a -
Insulation resistance meters, Sonel
MIC-5001 Insulation Resistance Meters
- Continuous reading of measured insulation resistance or leakage current
- Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
- Sound signalling of fi ve-second time intervals, facilitating capture of time characteristics
- Timing of measurement time T1, T2 and T3 for measurement of dielectric absorption ratio (DAR) and polarization index (PI)
- Reading of actual measurement voltage during measurement
- Protection against measurement of live objects
- Two- or three-lead method of insulation resistance measurement
- Power supplied by accumulator
- Instruments meet the requirements laid down by standard EN 61557
- The meter can be powered and charged from an external power adapter or from a car lighter socke
SKU: n/a -
Portable Instrument, Temperature measurement, Temperature Thermometers, TESTO, Testo Measuring Instruments
Mini surface thermometer – Mini surface thermometer
-42%Portable Instrument, Temperature measurement, Temperature Thermometers, TESTO, Testo Measuring InstrumentsMini surface thermometer – Mini surface thermometer
- Perfect for checking surface temperatures
- Extra wide measuring tip for placing on a flat measuring point
- Measurement of high temperatures up to +300 °C
- Many areas of application: heating engineering, sanitation sector, and air conditioning/ventilation/refrigeration technology
SKU: n/a -
Metravi, MOISTURE METER, PINLESS MOISTURE METER
MM-10 Digital Pinless Moisture Meter
- Pinless Moisture meter is an electronic dampness indicator with a measuring process working on the principle of high frequency measurement.
- Used for non-destructive tracing dampess in building materials of all kinds as well as for detecting damp distribution in walls, ceiling and floors.
- Suitable for pre-testing the readiness of building materials for covering prior to CM Measurment
- Quickly indicates the moisture content of materials
- Depth of penetration about 20 – 40mm
- Low battery Indication, Auto Power Off
- Max / Min Record Function.
- Data Hold
- White Backlit LCD Display
- Measuring Range: 0 to 100%
SKU: n/a -
Metravi, MILLION MEGOHMS METER, ANALOGUE MILLION MEGOHMS METER
MMM-1 Analogue Million MegOhms Meter
-26%Metravi, MILLION MEGOHMS METER, ANALOGUE MILLION MEGOHMS METERMMM-1 Analogue Million MegOhms Meter
- Ideal for measuring high resistance and insulation
- Output Test Voltage: 100V / 200V / 300V / 400V / 500V
- It has a measuring range of 1 MOhm to 10 Million M.Ohms
- Insulation Resistance Range available in 6 ranges.
- Accuracy: ±5%
- Overload Protection
- Visual warning for HT link
- Analogue Display
- Auxiliary Power Supply 220V AC
SKU: n/a -
Multifunction electrical installations meters, Sonel
MPI-530 Multifunction Electrical Installations Meter
-8%Multifunction electrical installations meters, SonelMPI-530 Multifunction Electrical Installations Meter
- Short circuit loop impedance (also in circuits secured with RCDs)
- RCD parameters
- Insulation resistance
- Earth resistance (4 measurement methods + soil resistivity measurement)
- Continuity of protective and equipotential bondings
- Light intensity measurement
- Phase sequence test
- Motor rotation direction test.
SKU: n/a -
RCD Meter, Sonel
MRP-201
- Testing of general, short delay and selective RCDs for the rated current values 10, 15, 30, 100, 300, 500 mA
- Measurement of IA trip current and tripping time tA for currents 0.5 IΔn, 1 IΔn, 2 IΔn, 5 IΔn
- RE and UB measurement without RCD tripping
- Extended AUTO function of RCD measurement
- Measurement of IA and tA during one RCD tripping
- Checking the correctness of PE connection using a contact electrode
- Measurement of voltage (0 … 500 V) and network frequency
- Memory of 990 results
- Wireless data transmission to a computer
SKU: n/a -
Earth resistance and resistivity meters, Sonel
MRU-21 Earth Resistance And Resistivity Meters
- Measurement of resistance of auxiliary electrodes RS and RH
- Measurement of interference voltage
- Selection of maximum measuring voltage (25 V and 50 V)
- Auto-zero function for the resistance of measurement leads (RCONT zero)
SKU: n/a -
Earth resistance and resistivity meters, Sonel
MRU-30 Earth Resistance And Resistivity Meters
- Measurement of auxiliary electrode resistances RS and RH
- Measurement of interference voltage
- Measurement in the presence of interference voltages in networks with frequencies of 50 Hz and 60 Hz
- Selection of maximum measurement voltage (25 V and 50 V)
- In ground resistivity measurements, distances between electrodes can be input in meters (m) or feet (ft)
SKU: n/a