Dark Light
-28%
,

DIT-200 Thermal Imagers And Pyrometers

Availability:

33 in stock


  • Precise non-contact temperature measurement
  • Emissivity is digitally adjustable from 0.10 to 1.00
  • Resolution from 0.1°C and 0.1°F
  • Laser pointer: circular
  • Displaying MAX, MIN, AVG, and DIF temperatures
  • Automatic Data Hold
  • Temperature unit selection: °C / °F
  • High and Low alarm.
  • Backlit LCD
  • Auto power off
  • Reinforced design for IP54 ingress protection

23,000.00  32,000.00 

33 in stock

*

Product Description

Temperature measurements with laser precision

Sonel DIT-200 is the pyrometer for professionals. Durable housing, ergonomic grip, buttons accessible with one finger – all this contributes to the comfort of the user. Technical parameters speak for themselves. The advanced laser pointer will precisely and unambiguously indicate the area of the performed measurement.

Technical data

Infrared temperature range - D:S, resolution

Infrared temperature range

D:S

Resolution

-50.0...999.9°C / -58.0...999.9°F

20:1

0.1°C / 0.1°F

1000°C / 1000...1832°F

20:1

1°C / 1°F

Infrared temperature range - accuracy

Infrared temperature range

Accuracy

-50...+20°C / -58...+68°F

±3.5°C / ±6.3°F

20...300°C / 68...572°F

±(1.0% m.v. + 1°C) / ±(1.0% m.v. + 1,8°F)

300...1000°C / 572...1832°F

±1,5% m.v.

Temperature range for K probe - resolution

Range

Resolution

-50.0…999.9°C / -58.0...999.9°F

0.1°C / 0.1°F

1000…1370°C / 1000...2498°F

1°C / 1°F

Temperature range for K probe - accuracy

Range

Accuracy

-50…0°C / -58…32°F

±2°C / ±3.6°F

0…1370°C / 320…2498°F

±(0.5% m.v. + 1,5°C) / ±(0.5% m.v. + 3°F)

Downloads

Datasheet :DIT-200

Instruction Manual : DIT-200

 

Videos

Sonel DIT-120 : Thermal Imager DIT-200

Unbox :DIT-200