Dark Light
-20%
,

PVM-1020

Availability:

33 in stock


 

  • It can be used for category 1 measurements according to IEC 62446-1.
  • AUTO mode for performing a sequence of measurements after one press of the START button.
  • It converts measured parameters into STC conditions according to IEC 60891 by cooperation with the IRM-1 solar radiation and temperature meter.
  • reSYNC function – automatic completion of results with environmental parameters and their conversion to STC conditions after restoring connection with IRM-1.
  • The built-in LoRa radio interface ensures cooperation with the IRM-1 meter over long distances.
  • Built-in Bluetooth module for communication with a computer.
  • Large measurement memory: 100 objects with 40 cells each.
  • Backlit display and buttons.

11,999.00  14,999.00 

33 in stock

*

Product Description

Great capabilities in a small casing

The Sonel PVM-1020 meter is probably the world’s smallest photovoltaic system meter with such a substantial number of measurement functions. The functions are selected with a rotary switch. Additional parameters are set with buttons located on the housing. All buttons and the graphic display are backlit, which greatly facilitates operation in shaded places, e.g. when taking measurements under ground-mounted PV systems. Large memory significantly shortens preparation of documents after the measurement.

Technical data

Parameter

Measurement range

Display range

Resolution

Accuracy

Voltage

AC voltage

0.0 V…600.0 V

0.0 V…600.0 V

0.1 V

±(2% m.v. + 2 digits)

DC voltage

0.0 V…1000.0 V

0.0 V…1000.0 V

0.1 V

±(0.5% m.v. + 2 digits)

Short circuit current ISC

0.0…20.0 A

0.0…20.0 A

0.1 A

±(1% m.v. + 2 digits)

Insulation resistance

Insulation resistance at AC side

Measuring voltage 250 V

250 kΩ…2.000 GΩ acc. to IEC 61557-2

0.0 kΩ…2.000 GΩ

from 0.1 kΩ

±(3% m.v. + 8 digits)

Measuring voltage 500 V

250 kΩ…5.000 GΩ acc. to IEC 61557-2

0.0 kΩ…5.000 GΩ

from 0.1 kΩ

±(3% m.v. + 8 digits)

Measuring voltage 1000 V

500 kΩ…9.999 GΩ acc. to IEC 61557-2

0.0 kΩ…9.999 GΩ

from 0.1 kΩ

±(3% m.v. + 8 digits)

Insulation resistance at DC side

Measuring voltage 250 V / 500 V / 1000 V

250 kΩ…1.000 GΩ acc. to IEC 61557-2

0.0 kΩ…1.000 GΩ

from 0.1 kΩ

±(3% m.v. + 8 digits)

Resistance of protective conductors and equipotential bondings

Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current

0.10 Ω…1999 Ω acc. to IEC 61557-4

0.00 Ω…1999 Ω

from 0.01 Ω

±(2% m.v. + 3 digits)

Measurement of resistance with low current

0.0 Ω…1999 Ω

0.0 Ω…1999 Ω

from 0.01 Ω

±(3% m.v. + 3 digits)

Current measurement

0.0 A…400.0 A

0.0 A…400.0 A

from 0.01 Ω

±(5% m.v. + 2 digits)

Power measurement

0.0 kW…100.0 kW

0.0 kW…100.0 kW

0.1 kW

±(6% m.v. + 5 digits)

Downloads

Datasheet : PVM-1020

Instruction Manual : PVM-1020 

 

Videos